Charge controller Victron Energy EasySolar MPPT 24/1600/40-16

https://avante.ua/web/image/product.template/1119/image_1920?unique=bda8ef4

Multifunctional Solar Energy Converter
The EasySolar device combines an MPPT solar charge voltage controller, inverter/charger and AC distribution system into one package. The product is easy to install and requires a minimum of wire connections.

INVERTER/CHARGER
Feed switch: 16 A

INVERTER
Input voltage range: 19 – 33 V
AC output 0 during intensive use: 16 A
Output AC1, 2, 3 Output voltage: 230 V AC ± 2%
Frequency: 50Hz ± 0.1% (1)
We'll have a long time. output power at 25°C (3): 1600 VA / 1300 W
We'll have a long time. output power at 40°C: 1200 W
Peak power: 3000 W
Maximum efficiency: 94%
No load power: 10W
No-load power in search mode: 3 W

CHARGER
AC input Input voltage range: 187-265 V AC
Input frequency: 45 – 65 Hz Power factor: 1
Absorption charge voltage: 28.8 V
Floating charge voltage: 27.6 V
Save mode: 26.4 IN
Home battery charge current (4): 40 A
Starter battery charge current (A): 4
Battery temperature sensor: Yes
Programmable relay (5): Yes
Protection (2) a – g

SOLAR CHARGER CONTROLLER
Model MPPT: 100/50
Maximum output current: 50 A
Maximum PV power, 6a,b): 1400 W
Maximum open PV voltage: 100 V
Maximum efficiency: 98%
Autonomous consumption: 10 mA
Absorption charge voltage, default value: 28.8 V
Float voltage, default value: 27.6 V
Charging algorithm: Multi-stage adaptive
Temperature compensation: -32 mV/°C
Protection: a – g

GENERAL CHARACTERISTICS
Operating temperature range: -20...+50°C (fan cooling)
Humidity (non-condensing): max. 95%
FRAME
Material and color: aluminum (blue, RAL 5012)
Protection category: IP 21
Battery connection: 1.5m battery cables
PV connection: Three sets of PV connectors MC4 (PV-ST01).
230 V AC connection: G-ST18i connector
Weight: 15 kg
Dimensions (H x W x D): 745 h 214 x 110 mm

STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emissions / Immunity EN 55014-1, EN 55014-2, EN 61000-3-3
Motor Vehicle Directive 2004/104/EC
1) Can be set to 60Hz and 240V
2) Protection
a. Output short circuit
b. Overload
With. Battery voltage too high
d. Battery voltage is too low
e. Temperature too high
f. 230 V AC at inverter output
g. Voltage ripple too high
3) Non-linear load, load factor 3:1
4) At 25°C
5) Programmable relay can be set to general alarm,
DC low voltage or generator on function
6a) When connecting PV power supply with higher power
the controller will limit the input power to 700 W or 1400 W,
respectively.
6b) PV voltage must exceed Vbat + 5V to
the controller started working.
Then the minimum PV voltage is Vbat + 1V.

1,407.00 € 1407.0 EUR 1,407.00 €

1,407.00 €