Hybrid inverter Victron Energy MultiPlus 12/500/20-16 (0.5 KVA/0.43 KW, 1 PHASE, WITHOUT MPPT)
Specifications
MultiPlus 12/500/20 – 120 VAC
PowerControl/PowerAssist
Not really
Gear switch
16A
INVERTER
Input voltage range
9.5–17 VDC
Output voltage
120VAC ±2%
Output frequency (1)
60Hz ±0.1%
Continued power output at 25°C (77°F) (3)
500VA
Continued power output at 25°C (77°F)
430 W
Continued power output at 40°C (104°F)
400 W
Continued power output at 65°C (149°F)
300 W
Peak power
900 W
Maximum efficiency
90%
No load power
6 W
Power search mode at zero load
2 W
CHARGER
AC input voltage range
95–140 VAC
AC Input Frequency Range
45–65 Hz
"Absorption" of charging voltage
14.4 V
Charge voltage "floating"
13.8 V
Storage mode
13.2 V
Charge the battery (4)
20A
Charge the starter battery current
1A
temperature sensor battery
Yes
GENERAL
Programmable relay (5)
Yes
Protection (2)
a – d
Working temperature
-40 to +65°C (-40 to +140°F), fan cooled
Humidity
Maximum 95%, no condensation
FRAME
Material and color
Steel/ABS, blue RAL 5012
Protection category
IP 21
Battery connection
16 mm²
230 V AC connection
Connector G-ST18i
Weight
4.4 kg
Dimensions (HxWxD)
311 x 182 x 100 mm
STANDARDS
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission/immunity
EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles
EEC R10-4
1) Can be adjusted to 50Hz.
2) Protection
A. Output short circuit
b. Overload
V. Battery voltage is too high
d. Battery voltage is too low
e. Temperature too high
f. 120 VAC inverter output
d. Input voltage ripple is too high
3) Non-linear load, crest factor 3:1
4) Temperature ambient up to 25°C (77°F)
5) Programmable relay that can be configured to:
general alarm, DC undervoltage or generator start/stop signal function
AC Rating: 230V/4A
DC Rating: 4A to 35VDC, 1A to 60VDC